AC meter testing up to 120 A (AC) and 320 V (AC)
The MTS310 source and test system uses the Reference Meter EPZ303, which is capable of measuring AC currents of up to 120 A. The new digital measuring system of the STM4000 series serves as an “error calculator”, i.e. it determines the measurement deviation of the DUT. The system is extendable for additional test positions. A necessary DUT connection can be supplied on request.
This test and source system can be used, for example, by manufacturers for charging stations for electric vehicles for stationary testing of AC charging stations.
Mechanical part
Safety components
Further optional components
- DTS100, Mobile computer and scanner
- DUT connection on request